Uploaded image for project: 'eCQM Issue Tracker'
  1. eCQM Issue Tracker
  2. CQM-4992

Add product code to allergen value set

XMLWordPrintable

    • Icon: EH/CAH eCQMs EH/CAH eCQMs
    • Resolution: Answered
    • Icon: Moderate Moderate
    • None
    • We plan to move forward with the proposed change during this annual update.

      Brief Description of Measure:

      ​CMS105/STK-6: Discharged on Statin Medication:
      Ischemic stroke patients who are prescribed or continuing to take statin medication at hospital discharge

      Description of Issue:

      The Statin Allergen value set  (OID: 2.16.840.1.113762.1.4.1110.41) currently aligns with the current CMS Measure Management System Blueprint standard and utilizes the SNOMED-CT substance code to identify a statin allergy.
       
      In preparation for future eCQM standard updates and harmonization efforts, The Joint Commission plans to add the SNOMED-CT product code 96302009 (HMG-CoA reductase inhibitor-containing product) to the existing value set as an alternate way to capture an allergy to a statin medication/product. 
      Proposed Solution:

      ​​Update TJC value set Statin Allergen (OID: 2.16.840.1.113762.1.4.1110.41) to include “product” code 96302009 (HMG-CoA reductase inhibitor-containing product). 

      Rationale for Change:

      Adding the product code will support future transition to changing standards. 

            JLeflore Mathematica EH eCQM Team
            MathematicaEHUpdates MathematicaEHUpdates